Operation
  1. Remove the protective cap and then turn on the meter by pressing the button ON/OFF
  2. Immerse the PH meter electrode in the solution to be tested. (auction: the liquid cannot be over the immersion line) and then stir gently to wait about 30 seconds till the reading stabilized. 
  3. Clean the electrode with pure or distilled water and dry it with tissue. Turn off the meter by pressing the “ON/OFF” button after testing,
  4. Take on the protective cap.
Note: Please calibrate the meter before use each time in case to get an accurate result.
 Calibration
  1. One-point calibration (only 6.86 point calibration, the accuracy is ±0.1PH)
  2. Dissolve the 6.86 buffer powder in 250 ml of distilled water.
  3. Turn the meter on by pressing the “ON/OFF” button, and immerse the electrode into the PH6.86 solution, gently stir and wait for 5 minutes.
  4. Press the “Cal” button to see the display number until the number is 5 and release the button then. To find the 6.86 calibration point display will start flashing 6.86 and wait until the display stops flashing. Then the one-point calibration finished.
  5. Two-point calibration ( the 4.00 and 9.18 point calibration, the accuracy is:±002PH)
  6. 00 point calibration: Dissolve 4.00 buffer powder in 250ml of distilled water, and immerse the electrode into PH 4.00 solution Press the “CAL” button to see displaying number is 5 and then release, display starts to flash 6.86, then press and release immediately the second time, reading will start to flash 4.00, and wait until the display stops flashing.
  7. 18-point calibration: Dissolve 9.18 buffer powder in 250ml of distilled water, immerse the electrode into PH 9.18 solution, Press the “CAL” button to see displaying number going to 5 then release, Display will start flashing 6.86, then press and release immediately the third time, reading will start to flash 9.18 and wait until the display stops flashing.
Note:
There will be ERR shown up on the screen if the meter was calibrated wrongly or in the air:
Maintenance
  1. the battery will be replaced if the display value is fuzzy or blank when the meter is turned on.
  2. The meter is warranted by Kacise for 12 months, the purchase invoice or proof should be supplied before returning the meter back.

    Range 0.00-14.00
    Resolution 0.01PH
    Accuracy ±0.1PH
    Power supply LR44 2cells
    Operation Temperature range 0℃–60℃
    Calibration One-point or Two Point.
    Dimension 155mmX31mmX18mm
    Net weight 55g(1.07oz)
    Automatic Calibration available