Industrial Brackish Water RO Treatment Systems

Global Water Mart is The Leader E-Commerce B2B Marketplace for Water Technology Products and Services

Menu
Industrial Brackish Water RO Treatment Systems
(0 reviews)
Get Price
(149) Views
(0) Contacts


Contact Company

Guangzhou Chunke Environmental Technology Co. Ltd
Guangzhou, China
(1329) Views
(25) Contacts

Industrial Brackish Water RO Treatment Systems are used to remove salt and purify water. This system consists of a booster pump, FRP/Carbon Steel pretreatment tanks (sand filter, activated carbon filter), SS304 cartridge filter housing, chemical dosing systems, high-pressure pump, FRP membrane pressure vessel, 4040 or 8040 membranes, control panel, and touch screen control.

  • Material and parts brands can be changed as regards raw water quality and customer demand.
  • From the touch screen panel, you can see all system flow diagrams and automatic or manual control of the system.
  • Membranes do not allow small particles, viruses, or bacteria to pass as a result your water becomes very clean and safe.
  • Industrial Brackish Water Desalination Plant Capacity range between 48m3/hour to 7500m3/day. If you need smaller than this capacity please see our commercial Brackish Water RO Plant.
If the water TDS is more than 1000ppm, we call this one brackish water. A different source of science books defines brackish water TDS as different. But if water does not tap water and seawater, and TDS between 100 to 12000 ppm, it can be called as brackish water.
All Brackish Water Treatment Plants are started by a booster pump, which feeds raw water to pretreatment tanks. Depending on capacity pretreatment tank size and numbers can be changed. Because of High TDS (Total Dissolved Solid) we usually use FRP and Carbon Steel Tanks but we can check your raw water source analysis and we can suggest alternative materials. If salt content and TDS are high, because of the corrosion, we are using FRP or Carbon Steel material for pretreatment tanks. 
Pretreatment consists of Sand Media Filter Tank, Activated Carbon Filter Media Tank, and Softener Tank which has ion exchange resin inside, they are very important for Brackish Water Desalination Plants.
Brackish Water RO Plant

Pretreatment is used to remove a large number of suspended solids, iron, turbidity, unwanted color, unpleasant taste, chlorine, sediment, organic contaminants, and odors. In pretreatment, we can control the flow manually or automatically for Brackish Water RO Plant.
After pretreatment water goes to the cartridge filter housing, we call it a security filter, most of the applications we are using stainless steel 304 or 316 material, but if water is very salty like brackish or seawater, we can use carbon steel or FRP or PVC Plastic Cartridge Filter Housing or Bag Filter Housing. There is a 1µm or 5 µm PP filter in the cartridge filter housing Brackish Water RO Plant.
After the cartridge filter housing, water goes to the membrane pressure vessel with High-Pressure Pump, you have a brand option for High-Pressure Pump and it allows you to adjust your budget. The membrane housing shell inside depends on capacity we have 4040 or 8040 Membranes. For most of our Brackish Water Treatment Plant project, we are using DOW Filmtec, Toray, Vontron, Hydranautics, and LG brand ro membranes. Membranes, in industrial Brackish Water Desalination Plants, are the most important part. They block if the particle size is bigger than 0.001µm and the molecular weight is up to 150-250Dalton. It consists of impurities, particles, sugars, proteins, bacteria, dyes, and organic and inorganic solids. Also, Brackish Water Treatment Plant systems can have chemical dosing at pretreatment or post-treatment, like anti-scaling (antiscalant), antifouling,  pH adjustment, Sterilization & Disinfection chemicals.
Brackish Water Treatment Plant

In Chunke when we check customer water analysis reports, sometimes because of scaling and fouling problems, we can use CIP (Clean In Place) System, which washes the membrane in membrane housing and makes the membrane life longer.
Electrical Power of industrial Brackish Water RO Plant

For industrial Brackish Water Treatment Plant needs 220-380V/50Hz/60Hz. For bigger capacity, because of the high-pressure pump, it needs 380V 50/60Hz. As regards your Brackish Water RO Plant machine design, we will check your electrical supply and decide to fix the power for you.
Before Buying Industrial Brackish Water Desalination Plant, you should know:
1. Pure Water Production Capacity (L/day, L/Hour, GPD).
2. Feed Water TDS and Raw Water Analysis Report (prevent fouling and scaling problems)
3. Iron and Manganese must be removed before raw water enters the membrane of the Brackish Water Desalination Plant
4. TSS (Total Suspended Solid) must remove before the industrial Brackish Water Treatment Plant‘s membrane.
5. SDI (Silt Density Index) must be less than 3
6. Must be sure your water source does not have oil and grease
7. Chlorine must be removed before industrial Brackish Water RO Plant
8. Available electrical power voltage and phase
9. Layout of place for industrial Brackish Water RO Plant
Membrane Sizes and Quantity for BWRO Water Treatment Plant 
Model Number 
Permeate Flow Rate 
 Membranes 
Liter/Hour 
Size 
Quantity 
CK-RO-2000L 
2000 
4040 
8-10 
CK-RO-3000L 
3000 
8040 
4 
CK-RO-4000L 
4000 
8040 
4-6 
CK-RO-5000L 
5000 
8040 
5-6 
CK-RO-6000L 
6000 
8040 
6-8 
CK-RO-8000L 
8000 
8040 
8-10 
CK-RO-10000L 
10000 
8040 
12 
CK-RO-15000L 
15000 
8040 
16-18 
CK-RO-20000L 
20000 
8040 
24-25 
CK-RO-30000L 
30000 
8040 
35-40 
CK-RO-45000L 
45000 
8040 
50-60 
CK-RO-100000L 
100000 
8040 
110-120 
CK-RO-200000L 
200000 
8040 
220-240 
Operation Specification for Industrial Brackish Water RO Plant 
Feed Water TDS > 1000ppm 
Hardness over 18ppm needs antiscalant dosing 
Turbidity must be removed 
Max. Feed Water Temp: 42°C 
Operate at higher TDS results in lower recovery 
H2S must be removed 
pH tolerance: 3-11 
Max. iron content: 0.05ppm 
 
 
Feed Water Pressure: 1.5 to 6 bar 
Max. Silica tolerance: 60ppm 
 
 
 
 
 

Features of Industrial Brackish Water Desalination Plant 
Standard Futers 
Available Options 
Programmable PLC Control 
Automatic Flush  
Motor Starter  
Ozone Generator 
Raw Water Feeding/Booster Pump 
UV Sterilizer 
Stainless Steel Cartridge Filter Housing 
Chemical Dosing 
FRP Membrane Housing 
pH control monitor 
Mitsubishi Processor Control 
ORP Control monitor 
Low-Pressure Switch 
Remote Control 
High-Pressure Switch 
Pretreatment System 
Liquid-filled pressure gauge 
Post Deionization Unit 
Stainless Steel 304 Frame 
CIP Membrane cleaning system 
Permeate Conductivity Monitor 
Touch Screen Control 
Raw Water Conductivity Monitor 
Tank Level Switch 
Membranes 
Customer Logo 
Control Valves 
 
 
Stainless Steel/UPVC Piping 
 
 